Violation Detail
Standard Cited: 19260452 G01 Additional requirements applicable to specific types of scaffolds.
Inspection Nr: 1821400.015
Citation: 01004
Citation Type: Serious
Abatement Status:
Initial Penalty: $16,550.00
Current Penalty: $16,550.00
Issuance Date: 10/29/2025
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 11/25/2025
Gravity: 10
Report ID: 0626700
Contest Date: 11/14/2025
Final Order:
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | C: Contested | 11/17/2025 | $16,550.00 | 11/25/2025 | Serious | |
| Penalty | Z: Issued | 10/29/2025 | $16,550.00 | 11/25/2025 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.452(g)(1): Each bracket, except those for wooden bracket-form scaffolds, was not attached to the supporting formwork or structure by means of one or more of the following: nails; a metal stud attachment device; welding; hooking over a secured structural supporting member, with the form wales either bolted to the form or secured by snap ties or tie bolts extending through the form and securely anchored; or, for carpenters' bracket scaffolds only, by a bolt extending through to the opposite side of the structure's wall: a) On or about April 29, 2025, on the northeast side of Tank A, employees jumped/lifted a Doka Climbing Formwork MF 240 scaffold from a lower ring level to ring level 7 without ensuring that the platform was secured to the Tank A form wall.