Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1810340.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,744.00
Current Penalty: $10,830.00
Issuance Date: 07/01/2025
Nr Instances: 1
Nr Exposed: 28
Abatement Date: 08/14/2025
Gravity: 10
Report ID: 1032500
Contest Date:
Final Order: 07/28/2025
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/28/2025 | $10,830.00 | 07/28/2025 | Serious | |
Penalty | P: Petition to Mod Abatement | 07/28/2025 | $10,830.00 | 08/14/2025 | Serious | |
Penalty | Z: Issued | 07/01/2025 | $12,744.00 | 07/28/2025 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: (a) On March 10, 2025, and at times prior thereto, employees performed maintenance and servicing activities on the Schurman Machine Incorporated Edger Saw Model No. 6TA60 Serial No. 2512.