Violation Detail
Standard Cited: 19260503 C03 Training requirements.
Inspection Nr: 1804435.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,268.00
Current Penalty: $6,488.00
Issuance Date: 08/07/2025
Nr Instances: 1
Nr Exposed: 7
Abatement Date: 09/24/2025
Gravity: 10
Report ID: 0418800
Contest Date:
Final Order: 08/29/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/29/2025 | $6,488.00 | 09/24/2025 | Serious | |
Penalty | Z: Issued | 08/07/2025 | $9,268.00 | 09/24/2025 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.503(c)(3): The employer did not retrain affected employees who already had been trained but demonstrated inadequate understanding and skill required by paragraph (a) of this section: a. On or about 02/13/2025, at 6450 NW 25th Street, Bldg. 704, Miami, Florida, due to the inadequacy to understand their need to use fall protection, employees from a crew performing pressure washing duties and another crew removing an existing roof and placing debris in garbage bags in close proximity to the skylights and roof edge, were exposed to 25-foot fall hazards when not using any type of fall protection.