Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1787707.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,729.00
Current Penalty: $4,729.00
Issuance Date: 01/16/2025
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 02/12/2025
Gravity: 5
Report ID: 0626600
Contest Date:
Final Order: 02/13/2025
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 01/16/2025 | $4,729.00 | 02/12/2025 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.219(d)(1):Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): On or about November 13, 2024, in the grinding area, employees operated a punch press to punch holes in material without a guard covering the belt and pulley on the machine.