Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1780586.015
Citation: 01004
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/20/2024
Nr Instances: 1
Nr Exposed: 8
Abatement Date: 12/17/2024
Gravity:
Report ID: 0418600
Contest Date:
Final Order: 12/17/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/17/2024 | $0.00 | 12/17/2024 | Other | |
| Penalty | Z: Issued | 11/20/2024 | $0.00 | 12/05/2024 | Other |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: a) Facility wide; On or about October 9th, 2024 and times prior the employer failed to certify that periodic inspections of the energy control procedures for equipment associated with Line 203 such as, but not limited to, the Extruder had been performed.