Violation Detail
Standard Cited: 19260451 F03 General requirements.
Inspection Nr: 1762586.015
Citation: 01004
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $2,765.00
Current Penalty: $2,765.00
Issuance Date: 01/14/2025
Nr Instances: 1
Nr Exposed: 5
Abatement Date:
Gravity: 5
Report ID: 0625400
Contest Date:
Final Order: 02/07/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 01/14/2025 | $2,765.00 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. On or about July 15, 2024, and at times prior thereto, employees were using a scaffold while performing plastering and painting work without having a competent person inspect the scaffold prior to work.