Violation Detail
Standard Cited: 19100178 A04 Powered industrial trucks.
Inspection Nr: 1754106.015
Citation: 01004
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $6,452.00
Current Penalty: $3,500.00
Issuance Date: 12/09/2024
Nr Instances: 1
Nr Exposed: 11
Abatement Date:
Gravity: 10
Report ID: 0213400
Contest Date: 12/18/2024
Final Order: 05/12/2025
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 05/12/2025 | $3,500.00 | Serious | ||
Penalty | C: Contested | 01/08/2025 | $6,452.00 | Serious | ||
Penalty | Z: Issued | 12/09/2024 | $6,452.00 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: a)Comanche Stainless LLC dba Diamond Brite Metals /333 Cedar Ave/Middlesex, NJ 08846 - Shop - Employees were exposed to struck by hazards while a 800lb Metal Beam was being transported by a Yale Sit-Down propane powered forklift (Model#ERC050; Serial#A968NO5211J) utilizing an unapproved boom attachment, the Boom Attachment has no Model/Serial# as it was made by employer. The forklift truck's data and capacity plates were not changed to reflect the attachment. Condition noted on or about 6/11/2024.