Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1753707.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $11,291.70
Issuance Date: 12/04/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 12/24/2024
Gravity: 10
Report ID: 0625500
Contest Date:
Final Order: 12/26/2024
Related Event Code (REC): A;C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/26/2024 | $11,291.70 | 12/24/2024 | Serious | |
Penalty | Z: Issued | 12/04/2024 | $16,131.00 | 12/24/2024 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(d)(4)(i):Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: At the ring remover: On or about June 07, 2024, and at times prior thereto, employees who were required to perform maintenance operations on the Ring Remover CR2450 where the electrical and pneumatic energy sources were not physically locked to prevent re-energization.