Violation Detail
Standard Cited: 19100147 C01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1748366.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,292.00
Current Penalty: $5,646.00
Issuance Date: 06/17/2024
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 10/11/2024
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 07/12/2024
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/12/2024 | $5,646.00 | 10/11/2024 | Serious | |
Penalty | Z: Issued | 06/17/2024 | $11,292.00 | 07/02/2024 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) Production; On or about May 15, 2024, and dates prior, an energy control program with procedures, employee training, and periodic inspections was not established and implemented before employees performed covered activities on the screen print press machines (big press - S. Rouge Model Roqprint You P08C06 M Serial No. RPB-1524).