Violation Detail
Standard Cited: 19100213 C01 Woodworking machinery requirements.
Inspection Nr: 1742308.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,610.00
Current Penalty: $2,000.00
Issuance Date: 09/24/2024
Nr Instances: 1
Nr Exposed: 7
Abatement Date: 05/01/2025
Gravity: 5
Report ID: 0316700
Contest Date:
Final Order: 10/24/2024
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/24/2024 | $2,000.00 | 05/01/2025 | Serious | |
| Penalty | Z: Issued | 09/24/2024 | $4,610.00 | 10/21/2024 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a) Assembly Room - A SawStop 10-inch Industrial Cabinet Saw used for ripping was not guarded, on or about April 18, 2024. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.