Violation Detail
Standard Cited: 19100254 D09 III Arc welding and cutting.
Inspection Nr: 1727404.015
Citation: 01004
Citation Type: Serious
Abatement Date: 07/10/2024 2
Initial Penalty: $6,453.00
Current Penalty: $3,871.80
Issuance Date: 06/20/2024
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0626600
Contest Date:
Final Order: 07/17/2024
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/17/2024 | $3,871.80 | 07/10/2024 | Serious | |
Penalty | Z: Issued | 06/20/2024 | $6,453.00 | 07/10/2024 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced. On or about February 12, 2024, in the welding area of the Machine Shop, the Metal Inert Gas (MIG) welder's conductor cable was split, exposing metal wires, while the worker was welding.