Violation Detail
Standard Cited: 19260651 C02 Specific Excavation Requirements.
Inspection Nr: 1726460.015
Citation: 01004
Citation Type: Serious
Abatement Date: 11/26/2024 5
Initial Penalty: $10,485.15
Current Penalty: $10,485.15
Issuance Date: 07/11/2024
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 0111400
Contest Date:
Final Order: 08/09/2024
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 07/11/2024 | $10,485.15 | 11/26/2024 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: Location: 50 Dwight St. Hanson MA. On or about 02/07/2024, an employee was exposed to cave in and caught between hazards while digging in a trench where a safe means of egress was not utilized or onsite.