Violation Detail
Standard Cited: 19100147 D05 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1724175.015
Citation: 01004
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $8,873.00
Current Penalty: $5,323.80
Issuance Date: 06/28/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 5
Report ID: 0420600
Contest Date:
Final Order: 08/06/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/06/2024 | $5,323.80 | Serious | ||
Penalty | Z: Issued | 06/28/2024 | $8,873.00 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(d)(5)(ii): Where there was a possibility of re-accumulation of stored energy to a hazardous level, verification of isolation was not continued until the servicing or maintenance was completed, or until the possibility of such accumulation no longer exists: (a) At the 1508 George Jenkins Blvd, Lakeland, Florida: On or about 6/13/2024; the verification of isolation was not completed while performing service and maintenance on the trim saw, exposing employees to struck-by hazards.