Violation Detail
Standard Cited: 19260651 I02 Specific Excavation Requirements.
Inspection Nr: 1706479.015
Citation: 01004
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,610.00
Current Penalty: $3,000.00
Issuance Date: 04/17/2024
Nr Instances: 1
Nr Exposed: 6
Abatement Date:
Gravity: 5
Report ID: 0215600
Contest Date:
Final Order: 06/24/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/24/2024 | $3,000.00 | Serious | ||
| Penalty | Z: Issued | 04/17/2024 | $4,610.00 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.651(i)(2):Excavation below the level of the base or footing of any foundation or retaining wall that could be reasonably expected to pose a hazard to the employees was not prohibited: On or about 10/27/2023, back of the house located at 99 Tennis Place, Flushing NY, 11375. Employees were exposed to cave-in hazards, while engaged in excavation operations at the worksite. Employees were working inside a trench measuring approximately 9ft deep, 14ft wide and 32ft long below the level of base and/or footing of the foundation and/or retaining wall without supporting systems.