Violation Detail
Standard Cited: 19100107 B05 I Spray finishing using flammable and combustible materials.
Inspection Nr: 1694049.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,250.00
Current Penalty: $2,800.00
Issuance Date: 09/21/2023
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 11/06/2023
Gravity: 5
Report ID: 0213600
Contest Date: 10/17/2023
Final Order: 03/14/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | J: ALJ Decision | 03/14/2024 | $2,800.00 | 11/06/2023 | Serious | |
| Penalty | C: Contested | 10/25/2023 | $6,250.00 | 11/06/2023 | Serious | |
| Penalty | Z: Issued | 09/21/2023 | $6,250.00 | 11/06/2023 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.107(b)(5)(i):The average air speed over the open face of the paint spray booth was less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. a) On or about 08/28/2023 in the powder spray booth; where the air flow across the face of the powder spray booth was 50 linear feet per minute or less exposing employees to health hazards. ABATEMENT CERTIFICATION REQUIRED