Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1680107.015
Citation: 01004
Citation Type: Other
Abatement Date: 3
Initial Penalty: $13,394.00
Current Penalty: $8,000.00
Issuance Date: 12/12/2023
Nr Instances: 1
Nr Exposed: 50
Related Event Code (REC):
Gravity: 5
Report ID: 0215800
Contest Date: 12/18/2023
Final Order: 12/13/2024
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 12/13/2024 | $8,000.00 | Other | ||
Penalty | C: Contested | 01/23/2024 | $13,394.00 | Serious | ||
Penalty | Z: Issued | 12/12/2023 | $13,394.00 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) ITT Goulds Pumps, Inc., 240 Fall Street, Seneca Falls, NY 13148: On or about 6/28/2023, Employees were not protected against caught by hazards when an employee operating a Cincinnati Bickford Radial Drill Press was exposed to the rotating spindle/chuck assembly.