Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1679342.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $15,625.00
Current Penalty: $0.00
Issuance Date: 11/02/2023
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 12/15/2023
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 11/28/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/28/2023 | $0.00 | 12/15/2023 | Serious | |
Penalty | Z: Issued | 11/02/2023 | $15,625.00 | 11/22/2023 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(c)(6)(i): Periodic Inspection. The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a) On or about June 26, 2023, the employer did not ensure that a periodic inspection of the energy control procedures for the Disamatic D3, located on line 2 in the Melt Department, has been completed at least annually.