Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1671379.015
Citation: 01004
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $12,278.00
Current Penalty: $8,595.00
Issuance Date: 09/25/2023
Nr Instances: 1
Nr Exposed: 5
Abatement Date:
Gravity: 5
Report ID: 0524500
Contest Date:
Final Order: 10/20/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/20/2023 | $8,595.00 | Serious | ||
Penalty | Z: Issued | 09/25/2023 | $12,278.00 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: On or about May 18, 2023, an employee was working around Sinto #6 Machine and was exposed to caught in hazards because the horizontal shaft was not adequately guarded.