Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1596500.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,702.00
Current Penalty: $0.00
Issuance Date: 11/08/2022
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 12/28/2022
Gravity: 5
Report ID: 0830500
Contest Date:
Final Order: 12/05/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/05/2022 | $0.00 | 12/28/2022 | Serious | |
Penalty | Z: Issued | 11/08/2022 | $8,702.00 | 12/28/2022 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a) Facility-wide: On or about 05/17/2022, the employer exposed employees to struck-by and caught-in hazards in that the employer did not adequately provide either authorized or affected employee training before employees performed servicing or maintenance on the equipment in the facility including but not limited to Welded Wire Machines 007, 603, 613, 634; Twisted Wire Machines T243, T244, T245; Press Brakes #36 and #61. Also, Punch Tool #38. There was no training for temporary employees.