Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
Inspection Nr: 1576173.015
Citation: 01004
Citation Type: Repeat
Abatement Status: Corrected During Inspection
Initial Penalty: $7,458.00
Current Penalty: $0.00
Issuance Date: 07/18/2022
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 5
Report ID: 0523400
Contest Date:
Final Order: 08/11/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/11/2022 | $0.00 | Repeat | ||
Penalty | Z: Issued | 07/18/2022 | $7,458.00 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): (a) On or about March 3, 2022, inclined belts on the shake-out were not guarded to prevent employees from accessing the belts when in operation, exposing employees to entanglement and caught-in hazards.