Violation Detail
Standard Cited: 19100334 A02 I Use of equipment.
Inspection Nr: 1575385.015
Citation: 01004
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $6,974.00
Current Penalty: $3,163.30
Issuance Date: 03/08/2022
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 5
Report ID: 0522500
Contest Date:
Final Order: 03/31/2022
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/31/2022 | $3,163.30 | Serious | ||
| Penalty | Z: Issued | 03/08/2022 | $6,974.00 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): a) Jegs High Performance Centers located at 751 East 11th Ave, Columbus, OH 43211: On and preceding January 31, 2022, a flexible extension cord and power cord for a large fan was not visually inspected for defects prior to use. the extension cord and fan cord had several areas with damaged insulation and other damage thereby exposing employees to electrical shock hazards. b) Jegs High Performance Centers located at 751 East 11th Ave, Columbus, OH 43211: On and preceding January 31, 2022, a power cord for a Skil 6265 drill was not visually inspected for defects prior to use. The outer jacket was pulled out from the bottom of the drill handle thereby exposing employees to electrical shock hazards.
Translate