Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1575193.015
Citation: 01004
Citation Type: Serious
Abatement Status: Not Completed - Worksite Changed
Initial Penalty: $4,351.00
Current Penalty: $4,351.00
Issuance Date: 05/10/2022
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 05/13/2022
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 06/16/2022
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 05/10/2022 | $4,351.00 | 05/13/2022 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Affordable Roofing at the site location of 4350 Weathervane Drive, Lorain, OH: The employer did not ensure that the two portable ladders used by employees to access the second level of a new residential home to perform roofing activities were extended 3 feet above the surface of the roof, exposing employees to fall hazards of approximately 13-24 feet to the ground below.