Violation Detail
Standard Cited: 19100147 D05 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1552242.015
Citation: 01004
Citation Type: Serious
Abatement Status:
Initial Penalty: $14,502.00
Current Penalty: $0.00
Issuance Date: 02/07/2022
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 02/24/2022
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 03/04/2022
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/04/2022 | $0.00 | 02/24/2022 | Serious | |
Penalty | Z: Issued | 02/07/2022 | $14,502.00 | 02/24/2022 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(d)(5)(i):Following the application of lockout or tagout devices to energy isolating devices, all potentially hazardous stored or residual energy were not relieved, disconnected, restrained, and otherwise rendered safe. a) Omnisource LLC is located at 1500 Old Bowman Street Road Mansfield, OH, 44903: On or about September 9, 2021, the employer failed to ensure that all potentially hazardous stored or residual energy was relieved, disconnected, restrained, and otherwise rendered safe. An employee was working on welding a baler ram of a Harris Baler Model TG 2102 where a lockout pin was removed resulting in the ram falling approximately 8 inches hitting the employee in the head and shoulder.