Violation Detail
Standard Cited: 19100134 G01 I A Respiratory Protection.
This violation item has been deleted.
Inspection Nr: 1527100.015
Citation: 01004
Citation Type: Serious
Abatement Status:
Initial Penalty: $13,653.00
Current Penalty: $0.00
Issuance Date: 10/14/2021
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 10/22/2021
Gravity: 10
Report ID: 0111400
Contest Date:
Final Order: 04/13/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/13/2022 | $0.00 | 10/22/2021 | Serious | |
Penalty | Z: Issued | 10/14/2021 | $13,653.00 | 10/22/2021 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: World Trade Center jobsite: On or about, April 23, 2021, employees that had significant facial hair that came between the sealing surface of the facepiece and their face, thus not ensuring an adequate face to facepiece seal, were required to use tight-fitting facepiece respirators .