Violation Detail
Standard Cited: 19260652 A01 Requirements for protective systems.
Inspection Nr: 1459191.015
Citation: 01004
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $13,494.00
Current Penalty: $6,747.00
Issuance Date: 06/18/2020
Nr Instances: 1
Nr Exposed: 5
Abatement Date:
Gravity: 10
Report ID: 0420600
Contest Date:
Final Order: 07/15/2020
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/15/2020 | $6,747.00 | Serious | ||
Penalty | Z: Issued | 06/18/2020 | $13,494.00 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). a. On or about 01/22/2020, at the site,Energy Florida - Customer Delivery Duke employees were exposed to possible cave-ins, in that, shoring, sloping or other protective measure were not used while in a trench excavation 4 feet wide, 14 feet long and 5 feet 8 inches deep with nearly vertical walls.