Violation Detail
Standard Cited: 19260703 A02 Requirements for cast-in-place Concrete.
This violation item has been deleted.
Inspection Nr: 1447831.015
Citation: 01004
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $13,494.00
Current Penalty: $0.00
Issuance Date: 05/18/2020
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC):
Gravity: 10
Report ID: 0522000
Contest Date: 06/30/2020
Final Order: 05/20/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 05/20/2021 | $0.00 | Serious | ||
Penalty | C: Contested | 06/30/2020 | $13,494.00 | Serious | ||
Penalty | Z: Issued | 05/18/2020 | $13,494.00 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.703(a)(2): "General requirements for formwork." Drawings or plans, including all revisions, for the jack layout, formwork (including shoring equipment), working decks, and scaffolds, shall be available at the jobsite. On Nov. 25, 2019, located on the 7th floor of a parking garage structure, employees placing wet concrete fell approximately 15' 4" to the next lower level when the formwork erected by another subcontractor collapsed. Approved engineered drawings were not available at the jobsite to account for a 24 inch thick slab fold area on the 7th floor and the employer, having been made aware of missing shoring calculations that were not submitted to the shoring designer and engineer, did not take reasonable alternative steps to protect its employees prior to the collapse of the formwork after placement of wet concrete.