Violation Detail
Standard Cited: 19260760 A01 Fall protection.
Inspection Nr: 1423617.015
Citation: 01004
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $26,254.00
Current Penalty: $6,000.00
Issuance Date: 12/26/2019
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 10
Report ID: 0134000
Contest Date: 01/31/2020
Final Order: 09/15/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/15/2021 | $6,000.00 | Other | ||
Penalty | C: Contested | 02/11/2020 | $26,254.00 | Repeat | ||
Penalty | Z: Issued | 12/26/2019 | $26,254.00 | Repeat |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems. Location - 75 Hayden Ave. Lexington, MA On or about 8/15/2019, employees were exposed to fall hazards to a lower level while working from outside the controlled decking zone "CDZ".