Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1404993.015
Citation: 01004
Citation Type: Serious
Abatement Date: 12/06/2019 2
Initial Penalty: $3,978.00
Current Penalty: $3,978.00
Issuance Date: 11/25/2019
Nr Instances: 2
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0625700
Contest Date:
Final Order: 12/23/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 11/25/2019 | $3,978.00 | 12/06/2019 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): On or about May 29, 2019, west side of the oil well site; the employee(s) utilized an oil rig (Mack Truck) while performing oil well servicing work with equipment not guarded: a) Westinghouse Max-XE-3 Phase Induction Motor crude oil pump pulley b) Dayton 20-inch fan pulley