Violation Detail
Standard Cited: 19260451 E01 General requirements.
Inspection Nr: 1399775.015
Citation: 01004
Citation Type: Serious
Abatement Status: Quick Fix
Initial Penalty: $2,415.00
Current Penalty: $2,415.00
Issuance Date: 05/21/2019
Nr Instances: 1
Nr Exposed: 4
Abatement Date:
Gravity: 5
Report ID: 0636900
Contest Date:
Final Order: 06/18/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 05/21/2019 | $2,415.00 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. On or about May 9, 2019, at a commercial construction site, masonry employees applying stucco from a (2) tier tubular welded frame scaffold were not provided with a ladder or other safe means of access. The employees were exposed to fall hazards of approximately up to (16) feet to the ground below.