Violation Detail
Standard Cited: 19100147 C07 I A The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1368442.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,260.00
Current Penalty: $0.00
Issuance Date: 02/25/2019
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 04/01/2019
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 03/13/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/13/2019 | $0.00 | 04/01/2019 | Serious | |
Penalty | Z: Issued | 02/25/2019 | $13,260.00 | 04/01/2019 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: Training which authorized employees received did not include: -Energy control procedures for specific equipment including but not limited to conveyors, Salvagnini S4, and the Banner Welder. -Type and magnitude of hazardous energy sources associated with specific equipment including but not limited to conveyors, Salvagnini S4, and the Banner Welder. -Recognition of energy isolation devices including but not limited to: pneumatic and hydraulic energy associated with the Salvagnini S4 and local electrical disconnects located on each of the Pack-out transfer conveyors.