Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1359806.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,467.00
Current Penalty: $3,400.00
Issuance Date: 12/14/2018
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 01/04/2019
Gravity: 5
Report ID: 0418100
Contest Date:
Final Order: 01/02/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/02/2019 | $3,400.00 | 01/04/2019 | Serious | |
| Penalty | Z: Issued | 12/14/2018 | $6,467.00 | 01/04/2019 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about 11/8/2018 at machinery including but not limited to the Travel Crete machine workers were exposed to injuries related to unexpected release of energies where the specific procedures were not inspected for completeness and accuracy on an annual basis. - Travel Crete machine was identified as deficient where there were no steps in writing for the motor to be locked out to prevent travel during maintenance or troubleshooting activities.