Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1357694.015
Citation: 01004
Citation Type: Serious
Abatement Date: 03/26/2019 2
Initial Penalty: $13,260.00
Current Penalty: $7,956.00
Issuance Date: 03/11/2019
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC): R
Gravity: 10
Report ID: 0419400
Contest Date:
Final Order: 04/09/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/09/2019 | $7,956.00 | 03/26/2019 | Serious | |
Penalty | Z: Issued | 03/11/2019 | $13,260.00 | 03/26/2019 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s). a. Banbury Mixer No. 3 - The employees were exposed to a crushing and amputation hazard. On or about October 31, 2018 the Banbury mixer operator attempted to clean rubber from the discharge door without locking out the mixer and inserting/tightening the safety bolts into the top of the discharge door.