Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1354483.015
Citation: 01004
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $5,314.00
Current Penalty: $2,784.00
Issuance Date: 01/28/2019
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 06/30/2019
Gravity:
Report ID: 0418300
Contest Date:
Final Order: 02/22/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | P: Petition to Mod Abatement | $2,784.00 | 06/30/2019 | Other | ||
Penalty | I: Informal Settlement | 02/22/2019 | $2,784.00 | 03/22/2019 | Other | |
Penalty | Z: Issued | 01/28/2019 | $5,314.00 | 02/22/2019 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: (a) On or about October 17, 2018 - Production area, the employer did not insure that all machine specific lockout and tagout procedures were reviewed at least annually such as, but not limited to, Press 36 Cleveland.