Violation Detail
Standard Cited: 19260651 H01 Specific Excavation Requirements.
Inspection Nr: 1332515.015
Citation: 01004
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $3,880.00
Current Penalty: $3,880.00
Issuance Date: 11/29/2018
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 10
Report ID: 0420600
Contest Date:
Final Order: 01/08/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 11/29/2018 | $3,880.00 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.651(h)(1): Employees were working in excavations in which there was accumulated water, or excavations in which water was accumulating, and adequate precautions had not been taken to protect employees against the hazards posed by water accumulation a) Corner of Old Pasco Road and Quail Hollow Blvd, Wesley Chapel - employees in the process of locating a directional boring drill head in an unprotected excavation were exposed to the hazards posed by water accumulation. Ground water was accumulating and runoff rain water was flowing into the excavation. Protective measures and/or water removal methods were not utilized, observed on or about 07/23/2018.