Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
This violation item has been deleted.
Inspection Nr: 1319033.015
Citation: 01004
Citation Type: Serious
Abatement Status:
Initial Penalty: $12,934.00
Current Penalty: $0.00
Issuance Date: 09/25/2018
Nr Instances: 2
Nr Exposed: 5
Abatement Date: 10/22/2018
Gravity: 10
Report ID: 0418100
Contest Date:
Final Order: 10/22/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/22/2018 | $0.00 | 10/22/2018 | Serious | |
Penalty | Z: Issued | 09/25/2018 | $12,934.00 | 10/22/2018 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: On or about May 14, 2018, employees were exposed to caught-by hazards when walking and working near the F&K printing press: a. Rotating shafts (print cylinders) on lacquer end of F&K printing press (1 set) b. Rotating shafts (print cylinders) on ink end of F&K printing press (3 sets) In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.