Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1309288.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,911.00
Current Penalty: $4,255.00
Issuance Date: 05/11/2018
Nr Instances: 1
Nr Exposed: 22
Abatement Date: 06/07/2018
Gravity: 5
Report ID: 0418100
Contest Date:
Final Order: 05/30/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/30/2018 | $4,255.00 | 06/07/2018 | Serious | |
Penalty | Z: Issued | 05/11/2018 | $6,911.00 | 06/07/2018 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: Trojan Battery Company, LLC, Lithonia, GA - In the Oxide Department, the water pumps for lines 1-8 had exposed horizontal rotating shafts. The rotating shafts were located approximately 55 inches from the floor, on or about 4/17/18.