Violation Detail
Standard Cited: 19100178 G02 Powered industrial trucks.
Inspection Nr: 1304886.015
Citation: 01004
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $9,239.00
Current Penalty: $5,543.55
Issuance Date: 06/08/2018
Nr Instances: 1
Nr Exposed: 8
Abatement Date: 07/13/2018
Gravity: 5
Report ID: 0522500
Contest Date:
Final Order: 07/02/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/02/2018 | $5,543.55 | 07/13/2018 | Serious | |
Penalty | Z: Issued | 06/08/2018 | $9,239.00 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.178(g)(2): Facilities shall be provided for flushing and neutralizing spilled electrolyte, for fire protection, for protecting charging apparatus from damage by trucks, and for adequate ventilation for dispersal of fumes from gassing batteries. a. On or about March 29, 2018, in the warehouse forklift charging area, the battery charging apparatus was not protected from damage by powered industrial vehicles.