Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1298689.015
Citation: 01004
Citation Type: Serious
Abatement Status: Not Completed - Employer Out of Business
Initial Penalty: $9,054.00
Current Penalty: $5,000.00
Issuance Date: 08/22/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 09/06/2018
Gravity: 10
Report ID: 0523900
Contest Date: 09/18/2018
Final Order: 12/26/2019
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 12/26/2019 | $5,000.00 | 09/06/2018 | Serious | |
Penalty | C: Contested | 09/20/2018 | $9,054.00 | 09/06/2018 | Serious | |
Penalty | Z: Issued | 08/22/2018 | $9,054.00 | 09/06/2018 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) The Accurpress 400 ton press; The employer did not ensure that lock out devices were affixed to the Accurpress 400 ton press while repairs were being performed.