Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1254051.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,803.00
Current Penalty: $1,773.00
Issuance Date: 08/18/2017
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 09/07/2017
Gravity: 10
Report ID: 0626300
Contest Date:
Final Order: 08/31/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/31/2017 | $1,773.00 | 09/07/2017 | Serious | |
| Penalty | Z: Issued | 08/18/2017 | $3,803.00 | 09/07/2017 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet above the upper landing surface to which the ladder was used to gain access: On or about August 11, 2017 at the location 2718 Beltline Road, Sunnyvale, TX, employees using two (2) 24-feet Werner extension ladders that were separated to make four (4) ladders. The ladders did not extend 3-feeet above the landing of the roof and exposing employees to a fall hazard. (a) On or about August 11, 2017 on the North side of the building, two 12-feet ladders did not extend 3-feet above the landing of the roof. (b) On or about August 11, 2017 on the South side of the building, two 12-feet ladders did not extend 3-feet above the landing of the roof.