Violation Detail
Standard Cited: 19260451 E01 General requirements.
Inspection Nr: 1232793.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,972.00
Current Penalty: $5,250.00
Issuance Date: 10/02/2017
Nr Instances: 2
Nr Exposed: 4
Abatement Date: 10/13/2017
Gravity: 5
Report ID: 0215000
Contest Date: 02/07/2018
Final Order: 07/18/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 07/18/2018 | $5,250.00 | 10/13/2017 | Serious | |
Penalty | C: Contested | 04/18/2018 | $6,972.00 | 10/13/2017 | Serious | |
Penalty | Z: Issued | 10/02/2017 | $6,972.00 | 10/13/2017 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: a) On or about 5/9/2017, At the jobsite: Employees were accessing and egressing a rolling scaffold located on the second floor by climbing the end rails which had spacing of two feet. Employees exposed to falls of eight feet. b) On or about 5/9/2017, At the jobsite: Employees were accessing and egressing a fabricated frame scaffold located in stairwell B. The employees were climbing the sides and cross bracing. Employees exposed to falls of 42 feet. Abatement certification is required for this item.