Violation Detail
Standard Cited: 19260452 B02 Additional requirements applicable to specific types of scaffolds.
Inspection Nr: 1218858.015
Citation: 01004
Citation Type: Serious
Abatement Date: 06/29/2017 2
Initial Penalty: $9,054.00
Current Penalty: $8,148.60
Issuance Date: 06/28/2017
Nr Instances: 1
Nr Exposed: 15
Related Event Code (REC):
Gravity: 5
Report ID: 0936300
Contest Date:
Final Order: 07/19/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/19/2017 | $8,148.60 | 06/29/2017 | Serious | |
Penalty | Z: Issued | 06/28/2017 | $9,054.00 | 06/29/2017 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.452(b)(2): Transverse bracing forming an "X" across the width of the scaffold was not installed at the scaffold ends and at least at every third set of posts horizontally (measured from only one end) and every fourth runner vertically. Bracing did not extend diagonally from the inner or outer posts or runners upward to the next outer or inner posts or runners: On March 24, 2017, inside the canopy at the main casino entrance, employees were working from tube and coupler scaffolding without transverse bracing installed across the width of the scaffold. Employees were exposed to fall hazards.