Standard Cited: 19100219 F03 Mechanical power-transmission apparatus.
Inspection Nr: 1210934.015
Citation: 01004
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $9,054.00
Current Penalty: $9,054.00
Issuance Date: 05/16/2017
Nr Instances: 3
Nr Exposed: 3
Related Event Code (REC):
Gravity: 5
Report ID: 0420600
Contest Date:
Final Order: 06/22/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 05/16/2017 | $9,054.00 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: a) Rack Conveyor - One end of the conveyor, which was 1 foot above the floor, had a chain and sprocket assembly that was inadequately guarded and the other end had an assembly that was unguarded, on or about February 16, 2017. b) Block Production Machine Area - There were 3 chain and sprocket assemblies for the conveyor that moved the metal plates around the machine, on or about February 16, 2017. All were within 3 feet of the floor. c) Cuber Machine - There was a chain and sprocket assembly, 2 feet above the floor, that was unguarded, on or about February 16, 2017.