Violation Detail
Standard Cited: 19260502 D21 Fall protection systems criteria and practices.
Inspection Nr: 1202794.015
Citation: 01004
Citation Type: Serious
Abatement Date: 08/18/2017 2
Initial Penalty: $12,548.00
Current Penalty: $9,666.00
Issuance Date: 07/10/2017
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 10
Report ID: 0418800
Contest Date:
Final Order: 07/31/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/31/2017 | $9,666.00 | 08/18/2017 | Serious | |
Penalty | Z: Issued | 07/10/2017 | $12,548.00 | 08/03/2017 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service: On or about January 13, 2017, at the above addressed jobsite, an employee working from a swing stage scaffold was using defective components in his personal fall arrest system such as a lifeline with burned areas, severe wear and paint, and a rope grab with a broken spring that were not removed from service.