Violation Detail
Standard Cited: 19261053 B04 Ladders.
Inspection Nr: 1201211.015
Citation: 01004
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $6,338.00
Current Penalty: $6,338.00
Issuance Date: 03/30/2017
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC):
Gravity: 5
Report ID: 0317900
Contest Date:
Final Order: 05/26/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 03/30/2017 | $6,338.00 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed: a) Construction site, Building 100, unit C2 - On or about January 6, 2017, employees used a six foot stepladder leaned against the wall studs to access the top plate and ceiling area work area.