Violation Detail
Standard Cited: 19261425 C03
This violation item has been deleted.
Inspection Nr: 1184386.015
Citation: 01004
Citation Type: Serious
Abatement Status:
Initial Penalty: $12,471.00
Current Penalty: $0.00
Issuance Date: 11/01/2016
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 11/07/2016
Gravity: 10
Report ID: 0626700
Contest Date: 11/30/2016
Final Order: 01/12/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/12/2018 | $0.00 | 11/07/2016 | Serious | |
Penalty | C: Contested | 12/01/2016 | $12,471.00 | 11/07/2016 | Serious | |
Penalty | Z: Issued | 11/01/2016 | $12,471.00 | 11/07/2016 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.1425(c)(3): 29 CFR 1926.1425(c)(3): The materials were not rigged by a qualified rigger. At the site on or about May 11, 2016; an E-17 exchanger weighing approximately 20,000 pounds was not rigged by qualified riggers, exposing employees to struck-by hazards.