Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1177830.015
Citation: 01004
Citation Type: Serious
Abatement Date: 03/29/2017 2
Initial Penalty: $5,070.00
Current Penalty: $2,500.00
Issuance Date: 03/03/2017
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0336000
Contest Date:
Final Order: 03/29/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/29/2017 | $2,500.00 | 03/29/2017 | Serious | |
Penalty | Z: Issued | 03/03/2017 | $5,070.00 | 03/29/2017 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: A.) Presque Isle Wine Cellars, Inc., 9440 West Main Street, North East, PA 16428, on or about September 15, 2016 and times prior thereto: Employees perform service and maintenance activities on equipment including, but not limited to, an auger, crusher and must pump. Employees were not locking out machinery when performing service and maintenance activities.