Violation Detail
Standard Cited: 19100177 D04 Servicing multi-piece and single piece rim wheels.
Inspection Nr: 1161756.015
Citation: 01004
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $12,471.00
Current Penalty: $15,000.00
Issuance Date: 09/23/2016
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity:
Report ID: 0134000
Contest Date:
Final Order: 02/08/2017
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/08/2017 | $15,000.00 | Other | ||
Penalty | Z: Issued | 09/23/2016 | $12,471.00 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.177(d)(4): The employer did not furnish or assure that employees use an air line assembly which includes a clip-on chuck, an inline valve with a pressure gauge or a presettable regulator, and a sufficient length of hose between the clip-on chuck and the in-line (if one is used) to allow the employee to stand outside the trajectory: (a) Location - 2 Presidential Way, Woburn, MA On or about 7/13/16, employees inflating tires were not required to use or provided an air line assembly which includes a clip-on chuck, an inline valve with a pressure gauge or a presettable regulator, and a sufficient length of hose between the clip-on chuck and the in-line (if one is used) to allow the employee to stand outside the trajectory.