Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1144786.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,000.00
Current Penalty: $2,500.00
Issuance Date: 07/29/2016
Nr Instances: 3
Nr Exposed: 1
Abatement Date: 09/15/2016
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 08/19/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/19/2016 | $2,500.00 | 09/15/2016 | Serious | |
Penalty | Z: Issued | 07/29/2016 | $5,000.00 | 09/15/2016 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard were being followed: a/ The employer is failing to protect employees from caught in hazards. This condition was last observed on and about 05/10/16, at 16051 MO-HWY 47, Marthasville, MO 63357. Periodic audits are not being performed on the energy control procedures belonging to the AIDA Hydraulic 220T Punch Press, m/n NCI-2000, s/n CC420-1149, SEYI Hydraulic 88T Punch Press, m/n Mark 88, s/n EW80-084, and Bliss Mechanical 22T Punch Press, m/n unknown, s/n EIH-H250.