Standard Cited: 19260651 K01 Specific Excavation Requirements.
Inspection Nr: 1118938.015
Citation: 01004
Citation Type: Serious
Abatement Status:
Initial Penalty: $7,000.00
Current Penalty: $7,000.00
Issuance Date: 06/10/2016
Nr Instances: 1
Nr Exposed: 7
Abatement Date: 06/22/2016
Gravity: 10
Report ID: 0215000
Contest Date: 03/28/2017
Final Order:
Related Event Code (REC): I;R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 04/14/2017 | $7,000.00 | 06/22/2016 | Serious | |
Penalty | Z: Issued | 06/10/2016 | $7,000.00 | 06/22/2016 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems. Site: 146 Wilson Street Brooklyn, NY On or about 12/14/15 a) Employer did not provide daily inspections by a competent person of an excavation which employees were working. The excavation in a back yard was being hand dug and was approximately 13 feet deep. Employees were trapped when a cave-in occurred.