Violation Detail
Standard Cited: 19100219 F03 Mechanical power-transmission apparatus.
This violation item has been deleted.
Inspection Nr: 1109683.015
Citation: 01004
Citation Type: Serious
Abatement Status: Quick Fix
Initial Penalty: $2,550.00
Current Penalty: $0.00
Issuance Date: 02/04/2016
Nr Instances: 1
Nr Exposed: 65
Abatement Date:
Gravity: 1
Report ID: 0418400
Contest Date: 03/03/2016
Final Order: 08/29/2016
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 08/29/2016 | $0.00 | Serious | ||
| Penalty | C: Contested | 03/10/2016 | $2,550.00 | Serious | ||
| Penalty | Z: Issued | 02/04/2016 | $2,550.00 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: a) Dryer's Area, Building PB1, on the Dryer, on or about 11-30-2015, employer failed to provide appropriate enclosure to protect employees working with and around the dryer's main chain and sprocket wheel drive, where the enclosure was not locked, which allowed employees access and contact whit the chain and sprocket wheel. b) Dryer's Area, Building PB1, on the Dryer, on or about 11-30-2015, employer failed to provide appropriate enclosure to protect employees working with and around the dryer's small gate's chain and sprocket wheel, where the chain and sprocket wheel was less than seven feet high.